SET_ALL_START_VALUES

Enter starting values for various quantities, such as velocities and potentials.

Syntax

set_all_start_values

Prompts

Start value for velocity of interface

A starting value for velocity at the named interface is required.

 

Start value for potential

A starting value for a potential at the named interface is required. If an AUTOMATIC value is specified the program attempts to determine a starting value and also selects a suitable component for which the potential is varied.

 

Varying species in interface

The species which potential is treated as unknown.

 

Automatic starting values for phase compositions

Compositions used as starting values in the equilibrium calculations using POLY-3. When using automatic starting values the compositions are taken from the entered profiles.