POTENTIAL_DIAGRAM
The POTENTIAL_DIAGRAM (POT or POTENTIAL) module is a potential phase diagram calculation module.
If you have a metal-oxide/sulphide-gas interaction system, you might want to calculate a so-called potential phase diagram given certain temperature and pressure. A potential diagram uses the activities of two major species in the gaseous mixture phase as mapping variables. The activities (that is, the fugacities at 1 bar) of these two species are typically set as the X- and Y-axis when the diagram is plotted. The phase relations between the gaseous mixture and various metal forms, metal-oxides, metal-sulphides, or other metal-bearing solids, are represented by different fields controlled by these two potential quantities.
To enter the module, at the SYS prompt type GOTO_MODULE POTENTIAL
.
There are no commands for this module. Follow the prompts and see About Potential Diagrams for details about how to calculate using potential diagrams.
Syntax |
POTENTIAL_DIAGRAM |
Prompts |
Database: /POT/ Press <Enter> and the program lists the available databases. Type one of the database names and press <Enter> to select. The following default elements are then based on the chosen database. |
Matrix element: /Fe/ |
|
First potential species: /S1O2/ |
|
Second potential species: /O2/ |
|
Temperature: /1000/ |