About the Martensite Temperatures Property Model

The Martensite Temperatures Property Model, available with the Property Model Calculator and the Steel Model Library, calculates the martensite start temperature (Ms) based on modeling the transformation barrier with fitted analytical equations. It is based on Stormvinter et al. [2012Sto] with subsequent update and extension by Gulapura Hanumantharaju [2017Gul] and Thermo‑Calc internal assessment. The partitionless equilibrium temperature T0 is calculated using the thermodynamic database. The Model also gives temperatures corresponding to 50%, 90%, and 99% transformations.

Martensite fractions are calculated with the same algorithm as in the Martensite Fractions Property Model.

To run calculations with the Steel Models requires a valid maintenance license plus licenses for both the TCFE (version 9 and newer) and MOBFE (version 4 and newer) databases. Also see our website to learn more about the Steel Model Library and other related examples.